Case Studies

1000kw Process Chiller Hire

1000kw Process Chiller Hire

1000kw process chiller hire to assist with a plastic injection moulding process.

1000kw Process Chiller Hire- The Challenge

The client was experiencing increasing production difficulties in the hot summer months due to on site chiller failures.

Importantly, chilled water performs the role of cooling the extrusion after the injection moulding process.

This situation was becoming critical and a production shut-down was looking increasingly imminent due to loss of cooling capacity.

An example of a temporary chilled water hosing system. This set was installed with temporary chillers- it allowed for the flow to be changed over between the clients pumps.

The Solution

A modular 1000kw chiller was installed to meet the cooling needs of the plant. The chiller was supplied with all hosing, pump and cable as required.

Water was pumped from the hot side of a mixing pit through the chiller and into the cool side, forming a primary circuit that was pumped into the building.

Significantly, the complete installation was installed in two days and completely met the cooling requirements when commissioned.

Summary

The chiller provided seamless operation for 4 months which allowed for full production capacity through the warm summer months.

Operating at consistent loads of 600-800Kw through-out the rental period, this installation was very reliable and as a result the customer minimised their losses.

1000kw Process Chiller Hire- notes

This Modular cooling rig is a modified Climaveneta BE/SRAT/SL3603 chiller.

Notably, the design criteria was to allow for increased flexibility of use. As such, this chiller is more portable, can be fitted into awkward areas and can be used in a 650 or 1000Kw configuration- a very flexible- powerful- reliable machine.

Products Used In This Case Study

700kw Chiller Hire
700kw Chiller Hire

700kw chiller hire made easy…..

View Product
Chilled Water Hose Hire
Chilled Water Hose Hire

Temporary chilled water hose and ancillaries rental from Advanced Climate Rentals.

View Product

How We've Helped Others In Your Sector

Industrial Chiller Hire in Kent for Pharmaceutical Production
Industrial Chiller Hire in Kent for Pharmaceutical Production

To supply industrial chiller hire in Kent consisting of a 1.1mw temporary chiller system acting as a contingency backup to the clients ammonia systems.

View Industry
2000kW Chiller Hire Project for District Cooling System
2000kW Chiller Hire Project for District Cooling System

1000kw process chiller hire to assist with a plastic injection moulding process. The client was experiencing increasing production difficulties in the hot summer months due to on site chiller failures. Chilled water performs the important role of cooling the extrusion after the injection moulding process.

View Industry
1000kW Process Chiller Unit Hire for a Major Pharmaceutical Manufacturer
1000kW Process Chiller Unit Hire for a Major Pharmaceutical Manufacturer

1000kw process chiller hire to assist with a plastic injection moulding process. The client was experiencing increasing production difficulties in the hot summer months due to on site chiller failures. Chilled water performs the important role of cooling the extrusion after the injection moulding process.

View Industry
Chemical Reactor Process Cooling Chiller Hire
Chemical Reactor Process Cooling Chiller Hire

Chemical reactor chiller hire for a major chemical production company. Syngenta approached ACR for a solution to their cooling needs at their KIP production facility.

View Industry
24/7
24/7 CALL-OUT 07976 329294
EMAIL US [email protected]